Professional AS1851-compliant hydrostatic testing services across Sydney, Central Coast, Newcastle, and the Hunter Valley.
GET YOUR FREE QUOTE NOWWhen it comes to fire protection systems, few tests are as critical—or as often overlooked—as the hydrostatic test. Apex Pumps provides AS1851-compliant hydrostatic testing for fire pumps, hydrant systems, booster assemblies, PRVs, and fire pipework.
Hydrostatic testing applies controlled water pressure to fire protection equipment to verify structural integrity, pressure capacity, and system reliability under fire conditions.
Hydrostatic testing is required every five years under AS1851 to ensure your system can withstand real-world emergency pressures. If your system has not been hydrostatically tested within the required interval, both compliance and insurance coverage may be at risk.
Hydrostatic testing reveals issues that cannot be detected through visual checks or routine annual maintenance.
| Typical Components Tested | Why It's Critical |
|---|---|
| Fire pump casings | Detects leaks, cracks, corrosion, and structural fatigue |
| Hydrant pipework and valves | Ensures the system can withstand brigade-assisted pressures |
| Booster assemblies | Validates AS1851 compliance |
| Pressure relief and reduction valves | Prevents system failure during fire events |
| Isolation and control valves | Provides verifiable evidence for insurance and certifiers |
| Fire service pipework | Reveals issues not detected through visual checks |
| Sprinkler system components | Ensures reliability under real-world fire conditions |
| Flexible couplings and fittings | Maintains system integrity and operational safety |
Maintain peak performance with our extensive inventory of genuine fire pump components and replacement parts.
Apex Pumps performs all hydrostatic tests in accordance with:
| Fire System Asset | Hydrostatic Test Frequency | Relevant Standard |
|---|---|---|
| Fire Pump Casings | Every 5 years | AS1851 / AS2941 |
| Hydrant System Valves & Components | Every 5 years | AS1851 |
| Booster Assemblies | 5-year integrity test | AS1851 |
| PRVs & Control Valves | 5-year overhaul & pressure test | AS1851 |
| Fire Pipework Under Pressure | Required testing | AS1851 |
Missing a hydrostatic test is one of the most common causes of AFSS non-compliance in NSW.
We begin with:
This ensures safe, accurate testing.
Using calibrated test equipment, we elevate pressure to AS1851/AS2941 levels:
We hold pressure and monitor:
During and after the test, we document:
If defects are found, isolation and urgent rectification may be required.
Every hydrostatic test includes:
Our reports meet fire certifier and insurer requirements.
Trust Apex Pumps for your hydrostatic testing needs with our proven expertise and commitment to AS1851 compliance.
Highly trained fire pump technicians with extensive experience in AS1851 and AS2941 compliance testing.
Professional-grade testing equipment calibrated to Australian Standards for precise pressure verification.
AFSS-ready documentation with pressure logs, photos, and certificates meeting fire certifier and insurer requirements.
Efficient testing processes with minimal disruption to your building operations.
Complete service including testing, defect identification, and rectification if required. Available across Sydney, Central Coast & Newcastle.
Hydrostatic testing exposes hidden failures that annual servicing cannot detect.
Hydrostatic testing is one of the most critical life-safety verifications for a building.
Apex Pumps provides hydrostatic testing for:
Apartment complexes & residential buildings
Offices & business facilities
Manufacturing plants & production sites
Shopping centres & retail spaces
Schools, hospitals & aged care facilities
Distribution centres & storage facilities
Public facilities & government properties
Subcontract testing services
Developers & construction projects
Comprehensive documentation and certification for complete compliance
Comprehensive reports with detailed pressure logs and duration records
Priority-ranked recommendations with severity classifications
High-resolution photos documenting all test points and findings
Optional step-by-step plan for addressing identified issues
Service logbook entries documenting all testing activities
Ready-to-submit documentation for fire certifiers
Ensure your fire system is compliant, safe, and ready for emergency operation. Apex Pumps provides fully certified AS1851 hydrostatic testing for fire pumps, hydrants, valves, and booster assemblies.
Sydney | Central Coast | Newcastle | Hunter Valley
GET FREE CONSULTATIONHydrostatic testing is required every 5 years for fire pumps, hydrant valves, booster assemblies, PRVs, and other key system components as specified in AS1851.
You risk:
Skipping hydrostatic testing exposes the building owner and strata committee to significant legal liability.
When performed incorrectly — yes.
When performed by trained AS1851 technicians — no.
Our controlled pressurisation prevents overloading while ensuring valid structural verification.
Most hydrostatic tests are completed within 2–4 hours, depending on building access and complexity.
Some buildings require notification depending on isolation requirements. We advise and assist with all necessary pre-test procedures.
Yes. We repair fire pumps, hydrant valves, PRVs, booster assemblies, fittings, flanges, controllers, and pipework defects.